HXV products are high voltage systems intended for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Standard HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2×4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banana jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.
HXV systems switch hi-pot, insulation resistance (IR) and other high-voltage test signals between instruments and devices under test. Standard systems are rated to 5000 VAC rms (7400 V peak) and 5 A, with 32 to 128 switch points per chassis, configured as 1xN multiplexers or NxM matrices. Custom systems go to 25 kV. Control is by Ethernet, RS232/USB or GPIB.
| Model | Configuration | Connector options |
|---|---|---|
| HXV/8×1 (HXV/8x1-BP, -SBP, -SHV) | 8x1 multiplexer, bidirectional mechanical relays; any or all relays may be closed; commons can be tied internally | BP binding post, SBP shrouded banana, SHV |
| HXV/4×2 (HXV/4x2-BP, -SBP, -SHV) | 4x2 matrix, bidirectional mechanical relays; any or all relays may be closed; the two commons can be tied internally | BP, SBP, SHV |
| HXV/8K (HXV/8K-BP, -SBP, -SHV) | 8 discrete relays, wired externally as any mux or matrix; also used to isolate lower-voltage circuits | BP, SBP, SHV |
| Parameter | Rating |
|---|---|
| Maximum voltage (carry) | 5000 VAC rms / ±7400 V peak breakdown |
| Hot switching voltage | ±1000 to ±3500 V (depends on relay) |
| Carry current | 5 A |
| Hot switching current | 3 A |
| Switch power | 50 to 200 W DC, or 2500 VA (depends on relay) |
| Switch time | 3 ms |
| Isolation | 1×1012 Ω |
| Relay life | 100 million cycles |
| Model | Switch points | Module slots | Height | Weight | AC power | Manual control (optional) |
|---|---|---|---|---|---|---|
| HXV/32-MF | 32 | 4 × 8x1 or 4x2 modules (or 4 × 8K in a 4 RU build) | 3 RU (5.25 in) | 15–25 lb (7–11 kg) | 75 W max | Pushbutton |
| HXV/96-MF | 96 | 12 × 8x1 or 4x2 modules (or 6 × 8K) | 4 RU (7.0 in) | 20–31 lb (9–14 kg) | 125 W max | Keypad with LCD |
| HXV/128-MF | 128 | 16 × 8x1 or 4x2 modules (or 8 × 8K) | 6 RU (10.5 in) | 25–35 lb (12–16 kg) | 170 W max | Keypad with LCD |
All chassis: 19 in (483 mm) rack width, 15 in (381 mm) deep, 110/220 VAC selectable, front-panel LEDs for switch and power status. Remote control by 10/100BaseT Ethernet, RS232/USB or GPIB (IEEE-488). HXV/32, /96 and /128 are also available as expansion chassis for a MESA controller (up to 16 chassis).
HXV routes a hi-pot tester or insulation-resistance meter to many test points automatically, so one instrument can test every pin, wire or winding of a cable, harness, connector, transformer or PCB without manual re-cabling.
Standard HXV systems carry up to 5000 VAC rms (7400 V peak) and can hot switch ±1000 to ±3500 V, depending on the relay. Custom HXV systems are built for up to 25 kV.
Use the HXV/8×1 multiplexer to connect one instrument to many points in turn. Use the HXV/4×2 matrix when the high and return leads both need to move, for example testing each conductor against every other. Use the HXV/8K discrete relays to build your own layout.
By Ethernet LAN, RS232/USB or GPIB from your test software, or from the optional front-panel pushbutton or keypad. See the manual control guide.
Yes. Custom HXV systems offer voltages to 25 kV, higher-current relays, custom mux or matrix sizes, separate driver chassis for EMP/EMC isolation, safety interlocks and application-specific connectors. Contact sales@cytec-ate.com or +1 585-381-4740.
To be configured for selected switch modules, purchased separately. Units larger than 32 channels come standard with the required LED Display modules. A complete 96 channel mainframe requires 12 display modules and a complete 128 channel mainframe requires 16 display modules. NOTE: If you do not require all 96 or 128 channels then you can request fewer display modules which will reduce the price of the system.
These Chassis controls up to four 8×1 or 4×2 modules, or up to four 8K modules in a slightly larger 4 RU chassis. LEDs on the front panel show switch and power status. Add Switch Modules and a Control Module to complete the system. Pushbutton Manual control is optional.
Dimensions:
19″ Rack Mount (483 mm)
15″ deep (381 mm)
5.25″ (3 RU) high (133 mm) but can be built as 4 RU to hold four 8K modules.
Weight: 15 to 25 lbs (7 to 11 Kg) max
AC Power : 75 Watts max. 110/220 selectable.
These Chassis controls up to twelve 8×1 or 4×2 modules, and can hold up to six 8K modules. One CP8 relay driver / display module is needed per switch module and these give you LED indication of switch status on the front panel. Add Switch Modules and a Control Module to complete the system. Keypad manual control with LCD display is optional.
Dimensions:
19″ Rack Mount (483 mm)
15″ deep (381 mm)
7.0″ (4 RU) high (178 mm)
Weight: 20 to 31 lbs (9 to 14 Kg) max
AC Power : 125 Watts max. 110/220 selectable.
These Chassis controls up to sixteen 8×1 or 4×2 modules, and up to eight 8K modules. LEDs on the front panel show switch and power status. Add Switch Modules, CP8 Driver Modules ( one per switch module ) and a Control Module to complete the system. Keypad Manual manual control with LCD display is optional.
Dimensions:
19″ Rack Mount (483 mm)
15″ deep (381 mm)
10.5″ (6 RU) high (270 mm)
Weight: 25 to 35 lbs (12 to 16 Kg) max
AC Power : 170 Watts max. 110/220 selectable.
Cytec can build custom high voltage systems up to 25 KV. Configurations are all done per customer request with many relay and connector options. Options include:
HXV/32, /96 and /128 are also built as expansion chassis that are used with a MESA Control Chassis. Multiple expansion chassis allow large or complex systems having one point of control to be confi gured, resulting in cost savings. Expansion chassis do not have control modules installed.
These switch modules use high reliability high voltage reed relays for applications up to 5000 VAC rms. Fast, high isolation reed relays are perfect for Hi-pot or IR testing. Switch times of 3 ms and life expectancy of 100 million operations. 5 way binding post / banana jacks, shrouded banana jack or SHV safety connectors are available on all modules.
Bi-directional high voltage mechanical relays.
Any or all relays may be on at once.
BP, SBP or SHV connector options.
Commons may be interconnected internally to minimize external connections on larger mux configurations.
100 Million cycle relay life.
3 ms switch times.
Bi-directional high voltage mechanical relays.
Any or all relays may be on at once.
BP, SBP or SHV connector options.
x2 Commons may be interconnected internally to minimize external connections on larger matrix configurations.
100 Million cycle relay life.
3 ms switch times.
Bi-directional high voltage mechanical relays.
Any or all relays may be on at once.
BP, SBP or SHV connector options.
Discrete relay configuration allows you to externally configure as any mux or matrix combination.
Use to isolate from lower voltage withstand components.
100 Million cycle relay life.
3 ms switch times.

Cytec can build custom configurations hand wired to provide high voltage switching of signals up to 25 KV and currents up to 160 amps. We use mechanical and solid state relays from a variety of vendors to provide the perfect system for the specs you need. Don't see what you need? Call us! We can help.