You don’t need a connection to the internet for this application to work, however it does use port 20034, so that will need to be unblocked across the network
When run this tool will open up a web browser page that displays any Cytec devices that are using an IF12 Control Module and responded to the discovery request. The “Config” link will take you to the configuration web page, as shown below. The “web” link will take you to the application web page.
Update Record
Configuration Settings can be programmed into the device by editing the settings and selecting the “Update Record” button. Note that the Reboot checkbox should normally be checked so that the device reboots and updates the network settings.
Configuration Settings
DeviceName: Interface name used for DNS and Net BIOS
DhcpDiscoverSec: Number of seconds after boot to wait before sending a DHCP Discover message. Default is 1.
MAC: MAC Address
SupressDefault: Disable Ping and UDP echo ports. Default is not supressed.
ActiveAddr: Current IP Address.
ActiveDNS1: Current DNS1 address.
ActiveDNS1: Current DNS2 address.
ActiveGate: Current Gateway address.
ActiveMask: Current IP Mask.
AutoIPAddr: Auto IP address.
AutoIPEN: Enable AutoIP feature. Default is enabled.
LocalName: Specify device access by name in the .local format. For example: mydevice.local
Mode: IP Address Mode:
DHCP(default)
DHCP with fallback to static
Static
Disabled
StaticAddr: Static IP Address.
StaticDNS1: Static DNS1 address.
StaticDNS2:Static DNS2 address.
StaticGate: Static Gateway address.
StaticMask: Static IP Mask.
Update Application
Revisions may be programmed into the Cytec device by obtaining an image file from one of our engineers, using the file selector to load it and selecting the “Send File” button. Note that the Reboot checkbox should be checked so that the device reboots and runs the new application. If you need assistance with this please call (585) 381-4740.